Overview

The NI-900 unit is designed to control and automate a variety of devices in single rooms or multiple small rooms and is capable of supporting devices with a variety of communication formats. It is configured to control a limited number of lights, thermostats, video displays and other equipment.

Common Application

Perfect for single rooms or two or more small rooms with a limited number of devices such as home theaters, MDUs, hotel rooms and other environments.

Features

1 Configurable RS-232 / RS-422 / RS-485 Serial port
3 IR / Serial ports
1 IR Receiver Port
4 Digital I/O ports
2 Communication Networks: AxLink and Ethernet (TCP/IP)
304 MIPS processor speeds
64 MB RAM
32 MB Flash Memory
512 KB Non-Volatile Memory
AMX Device Discovery enabled
JITC Compliant

DIMENSIONS (HWD)

1 9/16" x 5 9/16" x 5 1/8" (4.01 cm x 14.10 cm x 13 cm)
RU: 1

WEIGHT
1.30 lbs (590 g)

POWER

300 mA @ 12 VDC
Power requirements are usage dependant

ENCLOSURE
Metal with black matte finish

ONBOARD MASTER
304 MIPS

CERTIFICATIONS
FCC Part 15 Class B, CE, and IEC 60950

FRONT PANEL COMPONENTS

Program Port
Configuration DIP Switch: Sets the communication parameters for the Program port
IR RX LED: Red LED lights when IR data is being received via the rear IR RX port
IR LEDs: Three red LEDs light during the transmission of IR or Serial data via the rear IR port
I/O LEDs: Four yellow LEDs light when the rear I/O channels 1 - 4 are active. LED indicator for each I/O port reflects the state of that particular port
Serial LEDs
LINK/ACT: Green LED lights when the Ethernet cable is connected and an active link is established. This LED also blinks when receiving Ethernet data packets
Status: Green LED lights when the Controller is programmed and communicating properly
Output: Red LED lights when the Controller transmits data, sets channels sends data strings, etc.
Input: Yellow LED lights when the Controller receives data from button pushes, strings, commands, channel levels, etc.
ID Pushbutton: Sets the NetLinx ID (Device only) assignment for the device

REAR PANEL CONNECTORS

RS-232/422/485 (Port 1)
IR RX (Port 6)
Digital I/O (Port 5)
IR/Serial (Ports 2-4)
AxLink LED
AxLink Port: 4-pin 3.5 mm mini-Phoenix (male) connector provides data and power to external control devices
Ethernet Port: RJ-45 port for 10/100 Mbps communication. LEDs show communication activity, connection status, speeds, and mode information: - SPD (speed) - Yellow LED lights On when the connection speed is 100 Mbps and turns Off when the speed is 10 Mbps. - L/A (link/activity) - Green LED lights On when the Ethernet cables are connected and terminated correctly, and blinks when receiving Ethernet data packets.
Power Port: 2-pin 3.5 mm mini-Phoenix (male) connector

ENVIRONMENTAL

Operating Temperature: 0° C (32° F) to 50° C (122° F)
Operating Humidity: 20% to 85% RH
Heat Dissipation (Typical): 12.3 BTU/hr

INCLUDED ACCESSORIES
Three CC-NIRC IR Emitters

CI: 20949